Home About Us Safety Equipment Chemicals & Sealants Garments & Workwear Blog Contact Search products Get a Quote

Oil and gas is the least forgiving PPE environment in the UAE, and the one where buying on price causes the most damage. The hazards are not the everyday ones — they are flash fire, hydrogen sulphide, oxygen-deficient confined spaces, static discharge in flammable atmospheres and arc flash on live electrical work. Each has its own certification standard, and equipment certified for one offers no protection against another.

Flame-resistant clothing is where most enquiries start and where most specification errors happen. A coverall marked EN ISO 11612 is tested against heat and flame; one marked EN 1149 is antistatic, which matters in a flammable atmosphere but says nothing about flame resistance; NFPA 2112 is the North American flash-fire standard that many operators here specify instead. Inherently flame-resistant fabric and chemically treated fabric behave differently over a garment's service life, and treated fabric can lose protection through repeated industrial laundering. Tell us the standard your HSE department requires and how the garments will be washed, and we will quote to that.

Gas detection is the second area where we ask questions before quoting. A single-gas H2S detector suits a specific known hazard; a four-gas instrument covering H2S, CO, oxygen and combustibles suits confined-space entry where the atmosphere is unknown. Fixed-life and rechargeable units have very different total costs depending on how often the instrument is actually used. We supply both and will explain the trade-off rather than quoting whichever carries the better margin.

For respiratory protection the distinction that matters is filtering versus supplied-air. Half and full-face masks with A1/B1/E1/K1 or P3 cartridges to EN 14387 handle known contaminants at known concentrations. They are not adequate in oxygen-deficient atmospheres or unknown confined spaces, where escape sets and supplied-air equipment are required. We will not quote a cartridge respirator for an application that needs an escape set.

We also supply arc-flash protection rated by calorie value — jackets, hoods, face shields, balaclavas and gloves tested to ASTM F1959 — along with insulating gloves by voltage class for electrical maintenance work, and chemical-resistant epoxy coatings for plant flooring and bund areas.

Product Range

What We Supply

Across all three divisions on a single quotation. Technical data sheets available on request.

Flame-Resistant Coveralls supplied by Globix Trading in the UAE

Flame-Resistant Coveralls

FR and antistatic coveralls to EN ISO 11612 and EN 1149, in inherent and treated fabrics. Two-piece and one-piece, with reflective tape options.

Respiratory Protection supplied by Globix Trading in the UAE

Respiratory Protection

Half and full-face masks with gas, vapour and particulate cartridges to EN 14387, disposable FFP2 and FFP3 respirators, and emergency escape breathing devices.

Gas Detection supplied by Globix Trading in the UAE

Gas Detection

Single-gas H2S and multi-gas detectors covering H2S, CO, oxygen and combustibles. Fixed-life and rechargeable instruments with docking and calibration options.

Chemical-Resistant Gloves supplied by Globix Trading in the UAE

Chemical-Resistant Gloves

Nitrile, neoprene and butyl gloves to EN 374 for hydrocarbon and chemical handling, plus insulating gloves by voltage class for live electrical work.

Arc Flash & Face Protection supplied by Globix Trading in the UAE

Arc Flash & Face Protection

Arc-rated face shields, hoods and balaclavas tested to ASTM F1959, rated by calorie value, with helmet-integrated and standalone options.

Chemical-Resistant Coatings supplied by Globix Trading in the UAE

Chemical-Resistant Coatings

Two-component epoxy coatings for plant floors, bund areas and containment, with resistance to hydrocarbons, acids and process chemicals.

Applications

Where We Supply

Refineries and petrochemical plants
Tank farms and terminals
Offshore support and marine
Confined-space entry
Turnaround and shutdown works
Electrical maintenance
Pipeline and pigging operations
Laboratory and QC areas
Questions

Common Questions

Can you supply to an operator's approved vendor specification?

We can quote to a named standard and grade. Whether we can supply into a specific operator's approved vendor list depends on that operator's own registration process, which is separate from our trade licence. Tell us the requirement and we will be straight with you about whether we can meet it directly or whether it needs a registered channel.

What is the difference between EN ISO 11612 and EN 1149?

EN ISO 11612 covers protection against heat and flame. EN 1149 covers electrostatic dissipation, which prevents static discharge igniting a flammable atmosphere. They protect against different hazards, and many oil and gas specifications require a garment certified to both. Check which your HSE department has specified before ordering.

Do treated flame-resistant fabrics lose protection over time?

Chemically treated fabrics can lose flame-resistant performance through repeated industrial laundering, particularly with the wrong detergent or water temperature. Inherently flame-resistant fabrics retain protection for the garment's service life but cost more initially. Tell us your laundering arrangement and expected garment life and we will advise which works out cheaper over the period.

Do you supply gas detector calibration?

We supply detectors, calibration gas and docking stations. Calibration itself should be carried out on your schedule by a competent person — we can advise on interval and supply the consumables, but we do not certify instruments.

Need a Quote?

Send your requirement, specification and quantity — we will come back within 24 hours with pricing and availability.